Place of Origin: | CHINA |
Brand Name: | FUJI |
Certification: | GB98 |
Model Number: | FE-H |
Minimum Order Quantity: | 1unit |
---|---|
Price: | Negotiable |
Packaging Details: | Standard export package |
Delivery Time: | 15-35 days upon order approved |
Payment Terms: | T/T, L/C |
Supply Ability: | 1000//month |
Luxury 4 Persons Home Lift Elevators , Automotive Indoor Villa Lift
Overview
FUJI villa elevator adheres to the top-tech in the world’s private elevator field. It inherits the classical international design concept and deducts a luxurious dream in your home art. It grants a full play of an overall supreme quality at your home.
FUJI villa elevator integrates the art, pragmatism and the character of time into one. The machine room-less elevator enhances the degree of freedom to the architectural design. It is safe and reliable from the pit-less and run-through doors design. It is the most ideal up and down transport tool for the aged, the sick, and the handicapped. The pleasing decoration invents a overall harmonious effect to the indoor decoration. The highly efficient traction machine is integrated with variable voltage, variable frequency control and microprocessor control technology of high speed processing capability for accurate transmission of FUJI villa elevator enable your family enjoy smoother, securer and more comfortable service.
FUJI creates a clean and bright space which perfectly matches into harmony of your home. It adds more of the elevator interest and fulfills your villa elevator dream. FUJI villa elevator lets you fully enjoy the wonderful life.
Excellent Performance
1.More efficient use of building space: machine room-less innovative design, compact arrangement and space-saving, installation in any building without Hoistway.
2. Pleasing decoration: thorough car design, the rich material and a diversified combination
3. Safety and comfort & Environmental protection: maintenance-free and non-pollution permanent magnet synchronous and gearless traction machine
4. High efficiency, energy saving, comfort: 220V normal voltage, 1.1KW low energy consumption, variable voltage and variable frequency door governor system, low noise and low vibration, reasonable design of air conditioner
5. Easy and simple operation: the multiple door open modes for the users
6. The humane interface design: touch type operation button with the concise and eye-catching control panel, a service button, emergency stop button and an alarm button.
Standard Function
NO. |
Function Name |
Descriptionof functions |
1 |
Maintenance |
Elevator access to the overhaul state, the system automatically canceled and the operation of automatic doors. By the upper (lower) line will enable the elevator button to overhaul the speed of movement of the point (down) operation. Release the button to stop the lift immediately. |
2 |
The best curve |
Systems automatically computing the most suitable for the principle of human-machine function curve according to the distance needed to run, and is not subjected to restrictions on short floor and the number of constraints. |
3 |
Fire back to the base station |
Receive the fire signal, the elevator will not respond to any calls and inside command. The elevator run the fastest way to the fire station and then open the door and stop. |
4 |
Automatic back |
When beyond the setting time and there is no inside-call and outside-call ,elevators automatically return to the base station and wait for Passenger. |
5 |
Shaft parameters |
Before the first run, system must self-learn the well parameters. Including the story on each floor, forced deceleration switch, limit switch position. |
6 |
Staircase lock |
In automatically run state, after the elevator locked, the system eliminates all calls registered and then return to elevator-locked base station then open the door. After that the elevator stops running, closing the light and fan in car. |
7 |
Full load by pass |
Under the condition of run automatically without the driver, when the car with full load the elevator does not respond to outside-calls in passing floor. However, this time outside-calls can still be registered; it will be serviced next run-time. |
8 |
Car location |
When the elevator run to the end station ,the system automatically inspection and rectification of the location information based on the first level forced deceleration switch. At the same time, assisted by a special rate of forced deceleration. |
9 |
Lighting, fan |
When beyond the setting time and there is no inside-call and outside call the elevator will automatically turn off the light and fan in car. |
10 |
Hall call display by bit |
System allows the display of each floor using the 0-9, as well as any letters of permutation and combination of characters for use of the special conditions. |
11 |
Full selective |
When the elevator running in automatic or driver state will be responded to inside-call signal meanwhile responded to outside-call button signals, any service floor can call the elevator by register the up and down signal. |
12 |
Car arrival chime |
After the elevator arrival at the destination floor in accordance with the requirements of Passenger, the car roof board sent the signal. |
13 |
Overload |
When the lift when the load over the rated load; elevator alarm, stop the run. |
14 |
Light curtain |
When something block in the middle of the door during the door is closing, the light curtain protection action then the elevator turn to open the door. But the light curtain protection does not work in the fire operation. |
15 |
CPU fault |
System has three CPUs to judge state each other, if there is abnormal, the system block all output. |
Optional Function
NO. |
Function Name |
Descriptionof functions |
1 |
Maintenance |
Elevator access to the overhaul state, the system automatically canceled and the operation of automatic doors. By the upper (lower) line will enable the elevator button to overhaul the speed of movement of the point (down) operation. Release the button to stop the lift immediately. |
2 |
The best curve |
Systems automatically computing the most suitable for the principle of human-machine function curve according to the distance needed to run, and is not subjected to restrictions on short floor and the number of constraints. |
3 |
Fire back to the base station |
Receive the fire signal, the elevator will not respond to any calls and inside command. The elevator run the fastest way to the fire station and then open the door and stop. |
4 |
Automatic back |
When beyond the setting time and there is no inside-call and outside-call ,elevators automatically return to the base station and wait for Passenger. |
5 |
Shaft parameters |
Before the first run, system must self-learn the well parameters. Including the story on each floor, forced deceleration switch, limit switch position. |
6 |
Staircase lock |
In automatically run state, after the elevator locked, the system eliminates all calls registered and then return to elevator-locked base station then open the door. After that the elevator stops running, closing the light and fan in car. |
7 |
Full load by pass |
Under the condition of run automatically without the driver, when the car with full load the elevator does not respond to outside-calls in passing floor. However, this time outside-calls can still be registered; it will be serviced next run-time. |
8 |
Car location |
When the elevator run to the end station ,the system automatically inspection and rectification of the location information based on the first level forced deceleration switch. At the same time, assisted by a special rate of forced deceleration. |
9 |
Lighting, fan |
When beyond the setting time and there is no inside-call and outside call the elevator will automatically turn off the light and fan in car. |
10 |
Hall call display by bit |
System allows the display of each floor using the 0-9, as well as any letters of permutation and combination of characters for use of the special conditions. |
11 |
Full selective |
When the elevator running in automatic or driver state will be responded to inside-call signal meanwhile responded to outside-call button signals, any service floor can call the elevator by register the up and down signal. |
12 |
Car arrival chime |
After the elevator arrival at the destination floor in accordance with the requirements of Passenger, the car roof board sent the signal. |
13 |
Overload |
When the lift when the load over the rated load; elevator alarm, stop the run. |
14 |
Light curtain |
When something block in the middle of the door during the door is closing, the light curtain protection action then the elevator turn to open the door. But the light curtain protection does not work in the fire operation. |
15 |
CPU fault |
System has three CPUs to judge state each other, if there is abnormal, the system block all output. |